Need to reduce scale in a process chiller or compact cooling-water loop?
Review the actual chiller-water circuit, DN40 connection, 7 m³/h recommended flow and makeup-water chemistry before selection.

Product model: ID002
DN40 physical scale inhibition for industrial chillers, water-cooled process equipment and compact cooling loops operating at up to 12 m³/h.

Review the actual chiller-water circuit, DN40 connection, 7 m³/h recommended flow and makeup-water chemistry before selection.
Share the project market, quantity, schedule, pipe size, equipment data and water analysis for a focused response.
ScaleDp ID002 is an industrial chiller water scale inhibitor for DN40 flanged lines serving process chillers, water-cooled production equipment and compact cooling circuits. It is designed for normal operating flow near 7 m³/h and a maximum flow of 12 m³/h.
Hard-water deposits can form on chiller heat-transfer surfaces, strainers, valves and narrow cooling passages. The result may be higher approach temperature, reduced cooling capacity, increased compressor load, unstable process temperature or more frequent shutdown cleaning.
ID002 provides continuous physical scale control without salt, external power or a separate chemical dosing tank. It should be integrated with correct filtration, microbiological control, corrosion monitoring and manufacturer-required chiller water treatment.
Chiller Heat-Transfer ProtectionHelps reduce hard scale adhesion on water-side evaporator or condenser heat-transfer surfaces.
Cooling-Circuit Flow SupportSupports cleaner strainers, valves and narrow water passages in compact cooling loops.
Stable Process TemperatureCleaner water-side surfaces can support more consistent heat removal under stable operating conditions.
Continuous TreatmentOperates in-line whenever the chiller-water circuit is flowing.
No Salt or ElectricityNo brine tank, regeneration wastewater, electrical controller or magnetic power supply.
Retrofit-Friendly FlangeDN40 flanged construction supports installation into planned service piping with isolation valves.

Water passes through the internal multi-alloy DPSE structure. Localised electrochemical activity influences mineral crystallisation so hardness minerals are less likely to form hard, tightly bonded deposits on pipelines and heat-transfer surfaces.
ID002 is installed on a suitable DN40 chiller water line before the protected heat-transfer equipment.
The DPSE core acts on mineral crystallisation without salt, magnets or an external electrical power supply.
Calcium and magnesium remain in the water with a reduced tendency to form hard, bonded mineral scale under suitable conditions.
Download the model-specific parameter card and supporting product documents. Contact ScaleDp for project selection and submittal support.
Dimensions, flange data, flow range, pressure and temperature information for ID002.
Download PDF ›
CatalogueCompare residential, commercial, industrial and irrigation scale-control models.
Download PDF ›
ComplianceAvailable compliance information for technical review.
Download PDF ›
Project supportSend flow, pipe size, water quality and application data for a focused response.
Contact technical team ›
These answers clarify product scope, installation, monitoring and the engineering information needed before final selection.
ID002 is intended for DN40 industrial chiller and process-cooling water lines operating between 2 and 12 m³/h, with a recommended design flow of 7 m³/h.
It may be used in a compatible closed loop, but the loop chemistry, inhibitor package, dissolved oxygen, filtration and actual circulation path must be reviewed before installation.
No. It does not replace microbiological control, corrosion inhibition, filtration or the chiller manufacturer’s water-quality requirements.
Installation may be on the makeup-water line or an engineered circuit position upstream of the protected heat-transfer surfaces. The correct location depends on loop design and actual flow.
Track approach temperature, supply and return temperature, pressure drop, cooling capacity, compressor load, cleaning interval and visible deposit condition.
ID002 itself needs no external power, salt or dedicated chemical dosing. Other site-required water-treatment programs may still be necessary.
Provide the piping diagram, chiller model, DN40 connection details, flow trend, temperature, pressure and water analysis.
ScaleDp supports distributors, contractors, OEMs, engineering companies and plant buyers with product selection and project documentation.
Review normal, recommended and peak flow, pressure, DN, temperature and installation layout before model confirmation.
Use water chemistry, operating trends and deposit analysis to separate mineral scale from other fouling.
Model parameter card, catalogue, compliance information and qualified project-submittal support.
Distributor communication, product training and qualified OEM/ODM cooperation for industrial projects.
Send the equipment information and our team will help confirm ID002 suitability.