Need to keep condenser water passages and heat-transfer surfaces cleaner?
Confirm condenser type, DN80 line size, 27 m³/h recommended flow, temperature and water-treatment program before selecting ID005.

Product model: ID005
DN80 physical scale inhibition for water-cooled and evaporative condenser circuits in refrigeration, HVAC and industrial heat-rejection systems.

Confirm condenser type, DN80 line size, 27 m³/h recommended flow, temperature and water-treatment program before selecting ID005.
Share the project market, quantity, schedule, pipe size, equipment data and water analysis for a focused response.
ScaleDp ID005 is an industrial condenser water scale inhibitor for DN80 flanged lines. It is intended for water-cooled condensers, evaporative condensers, refrigeration plants and heat-rejection circuits operating within 9-50 m³/h.
Condenser scale increases thermal resistance and can raise condensing temperature or pressure. Operators may see reduced capacity, higher compressor energy, unstable approach temperature, restricted flow or more frequent tube and coil cleaning.
ID005 supports continuous mineral-scale control without salt or external power. Refrigerant safety, microbiological control, corrosion treatment, filtration and condenser manufacturer requirements remain unchanged.
Condenser Surface ProtectionHelps reduce hard scale adhesion on tubes, coils and water-side condenser surfaces.
Heat-Rejection SupportCleaner surfaces can support more stable condensing temperature and heat transfer.
Tube and Coil Flow SupportHelps reduce mineral buildup that can narrow condenser water passages.
Reduced Cleaning PressureContinuous scale control may support longer intervals between deposit-related cleaning events.
Power-Free DeviceID005 requires no electrical supply, salt regeneration or separate controller.
DN80 Flanged IntegrationDesigned for industrial water piping with appropriate isolation and service clearance.

Water passes through the internal multi-alloy DPSE structure. Localised electrochemical activity influences mineral crystallisation so hardness minerals are less likely to form hard, tightly bonded deposits on pipelines and heat-transfer surfaces.
ID005 is installed on a suitable DN80 condenser water line before the protected tubes, coils or heat-transfer surfaces.
The DPSE core acts on mineral crystallisation without salt, magnets or an external electrical power supply.
Calcium and magnesium remain in the water with a reduced tendency to form hard, bonded mineral scale under suitable conditions.
Download the model-specific parameter card and supporting product documents. Contact ScaleDp for project selection and submittal support.
Dimensions, flange data, flow range, pressure and temperature information for ID005.
Download PDF ›
CatalogueCompare residential, commercial, industrial and irrigation scale-control models.
Download PDF ›
ComplianceAvailable compliance information for technical review.
Download PDF ›
Project supportSend flow, pipe size, water quality and application data for a focused response.
Contact technical team ›
These answers clarify product scope, installation, monitoring and the engineering information needed before final selection.
ID005 is intended for DN80 water-cooled or evaporative condenser circuits operating from 9 to 50 m³/h, with 27 m³/h recommended.
Reducing new hard scale adhesion may support condenser heat transfer, but pressure results also depend on refrigerant charge, airflow, water flow, ambient conditions, fouling and equipment condition.
No. Existing heavy scale, biofilm, corrosion products or oil contamination may require cleaning and inspection. ID005 supports ongoing scale control after a safe baseline is established.
The location is normally upstream of the condenser water inlet or at a correctly engineered makeup/circulation point where the protected flow passes through the device.
ID005 only contacts the water circuit. It does not enter or modify the refrigerant circuit, and all refrigerant safety rules remain unchanged.
Track condensing temperature and pressure, approach temperature, water flow, pressure drop, compressor energy, cleaning interval and deposit condition.
Provide condenser type, water-side DN and flow, temperatures, pressure, cooling load, water report, treatment program, cleaning records and layout.
ScaleDp supports distributors, contractors, OEMs, engineering companies and plant buyers with product selection and project documentation.
Review normal, recommended and peak flow, pressure, DN, temperature and installation layout before model confirmation.
Use water chemistry, operating trends and deposit analysis to separate mineral scale from other fouling.
Model parameter card, catalogue, compliance information and qualified project-submittal support.
Distributor communication, product training and qualified OEM/ODM cooperation for industrial projects.
Send the equipment information and our team will help confirm ID005 suitability.