Large Industrial Pipeline Scale ControlDN150

Industrial Pipeline Scale Inhibitor & Descaler

Product model: ID008

DN150 physical scale inhibition and descaling support for large industrial process-water pipelines, transfer lines and water-injection systems up to 180 m³/h.

Typical application

Up to 95%Scale inhibition*
95 m³/hRecommended flow
1.6 MPaMaximum pressure

See technical information ↓

For engineers & plant operators

Need scale control for a large DN150 industrial pipeline?

Confirm 95 m³/h recommended flow, pressure profile, water chemistry, deposit analysis and downstream distance before selecting ID008.

Review product specifications ›

For distributors & project buyers

Need pricing, documentation or technical selection support?

Share the project market, quantity, schedule, pipe size, equipment data and water analysis for a focused response.

Start a B2B inquiry ›

Large-flow scale inhibition for industrial pipelines

ScaleDp ID008 is an industrial pipeline scale inhibitor and physical descaler for DN150 flanged water lines. It is the largest standard model in the ID001-ID008 range, with a stated flow range of 32-180 m³/h and 95 m³/h recommended.

Pipeline scale can reduce effective diameter, increase pressure loss, lower transfer capacity and place additional load on pumps and valves. In water-injection and heated transfer systems, changing temperature, pressure and water mixing can increase mineral precipitation risk.

ID008 supports continuous physical scale control for compatible mineral deposits. It does not replace filtration, corrosion control, pigging, chemical cleaning, integrity management or deposit-specific treatment for wax, biofilm, iron sulfide and other non-mineral fouling.

  • 01

    DN150 Pipeline Scale ControlDesigned for large industrial water lines with up to 180 m³/h stated maximum flow.

  • 02

    Flow-Capacity SupportHelps reduce hard mineral buildup that can narrow effective pipe diameter.

  • 03

    Pressure-Loss ManagementCleaner internal surfaces can support more stable hydraulic performance.

  • 04

    Descaling SupportContinuous treated-water exposure may help compatible existing mineral deposits loosen gradually.

  • 05

    Power-Free In-Line DeviceRequires no electrical controller, magnetic coil or salt regeneration system.

  • 06

    Project and OEM SupportSuitable for engineered pipeline projects requiring flange data, documentation and technical review.

ID008 model
Selected modelID008
ConnectionDN150 flange
Recommended / max flow95 m³/h / 180 m³/h

Confirm project fit

ID008 product details

Basic product information
Product type
Industrial Physical Water Scale Inhibitor
Product model
ID008
Nominal diameter
DN150
Connection
Flange
Flange thickness
24 mm
Flange bolt hole × quantity
Φ22 × 8
Overall diameter
Φ285 mm
Length
530 mm
Performance & operating conditions
Scale inhibition
Up to 95% under stated test and operating conditions
Minimum flow
32 m³/h
Recommended flow
95 m³/h
Maximum flow
180 m³/h
Maximum pressure
1.6 MPa
Ambient temperature
5-280°C
Installation requirements
Recommended position
Install at an engineered DN150 position upstream of the pipeline section or equipment requiring mineral-scale protection. Provide isolation, bypass, lifting clearance, pressure monitoring and safe maintenance access.
Connection
DN150 flanged in-line installation
Power requirement
None
Salt / dedicated chemical requirement
None for the ScaleDp device; retain any site-required treatment program
Service access
Provide isolation, bypass where required, safe lifting clearance and inspection access
Selection data required
Pipeline DN and length, normal/peak flow, pressure profile, temperature changes, water sources and mixing points, hardness, alkalinity, sulfate, silica, barium, strontium, iron, TDS, deposit analysis, corrosion history and cleaning method.
Certificates & technical documents
Industrial applications
Industrial Process-Water PipelinesScale control for large water-transfer lines serving production facilities.
Oilfield Water-Injection LinesSupports mineral-scale control in compatible injection-water piping after water analysis.
Heated Water PipelinesHelps reduce temperature-driven mineral deposits in industrial transfer systems.
Plant Utility-Water NetworksSuitable for large DN150 utility-water mains and distribution branches.
Raw-Water Transfer LinesCan be evaluated after suspended solids, iron and biological risks are addressed.
Large Circulating-Water SystemsFor industrial circulation branches operating within the ID008 hydraulic range.

How physical industrial scale control works

Water passes through the internal multi-alloy DPSE structure. Localised electrochemical activity influences mineral crystallisation so hardness minerals are less likely to form hard, tightly bonded deposits on pipelines and heat-transfer surfaces.

Explore DPSE technology

  1. 01Water enters the device

    ID008 is installed on an engineered DN150 process or water-injection line before the downstream section requiring mineral-scale protection.

  2. 02Physical treatment takes place

    The DPSE core acts on mineral crystallisation without salt, magnets or an external electrical power supply.

  3. 03Treated water moves downstream

    Calcium and magnesium remain in the water with a reduced tendency to form hard, bonded mineral scale under suitable conditions.

From industrial product evaluation to project delivery

ScaleDp supports distributors, contractors, OEMs, engineering companies and plant buyers with product selection and project documentation.

01

Hydraulic selection

Review normal, recommended and peak flow, pressure, DN, temperature and installation layout before model confirmation.

02

Water and deposit review

Use water chemistry, operating trends and deposit analysis to separate mineral scale from other fouling.

03

Technical documents

Model parameter card, catalogue, compliance information and qualified project-submittal support.

04

Channel and OEM support

Distributor communication, product training and qualified OEM/ODM cooperation for industrial projects.

ID008 INDUSTRIAL PROJECT INQUIRY

Have your flow rate, pipe size and water data ready?

Send the equipment information and our team will help confirm ID008 suitability.

Industrial scale-control applications ›

Send Project Details ›