RESIDENTIAL SCALE CONTROL When cold water runs normally but hot water is weak, mineral deposits are one possible clue rather than a diagnosis. This page helps separate a local fixture restriction from a wider heater or pipework issue, explains why existing obstructions may need service first, and shows where whole-house scale control can fit after the actual problem has been assessed. 01 / APPLICATION FIT Use the actual municipal or well-water analysis, including any pretreatment results. Identify whether a recent source-water change, filter replacement, pump adjustment or service event coincided with the symptom instead of attributing it to hardness alone. Domestic storage, tankless or heat-pump water heater. Record the model, service history, inlet screen or strainer where fitted, mixing arrangement and any recirculation system; different heater types have different operating and maintenance requirements. Map filters, the softener, pressure regulator or pump, heater isolation valves and the affected fixtures. A loaded filter, restricted aerator, partly closed valve or heater-side restriction can require a different response from new-scale prevention. These are product-selection limits. A full water assessment may identify other treatment needs. 02 / SIMULTANEOUS DEMAND A restricted outlet can make a system appear to need less flow than the household actually requires. The hypothetical inputs below represent the intended simultaneous use after necessary repairs or cleaning; they are not measurements of a faulty installation. WD001 recommended flow is 3 m³/h (50 L/min); maximum flow is 4 m³/h (approximately 66.7 L/min). Use the recommended duty for selection, then check pressure loss and water quality. Maximum flow is not a continuous-design recommendation. The example totals 27 L/min (1.62 m³/h). Confirm the available supply and heater performance at that intended duty. Adding an in-line device introduces another hydraulic component, so review pressure-loss data rather than expecting a pressure increase. 03 / MAIN-LINE LAYOUT After the cause of the existing restriction has been assessed, consider WD001 after required pretreatment and before the downstream circuit needing new-scale control. A whole-house position and a heater-only inlet position have different coverage; neither bypasses an unresolved obstruction inside existing equipment. 04 / MODEL REFERENCE Check the supplied version against the water report, hydraulic duty and installation conditions. 05 / PERFORMANCE CHECKS 06 / BEFORE SELECTION Send the hot and cold outlet observations, heater model, service history, water report and treatment-layout photos. We can review WD001 suitability for the intended duty and clarify which site information is needed before discussing a scale-control position. No. It narrows the investigation to the relevant hot-water path, but local fittings, valves, heater components and pipework still need assessment. The pattern alone does not identify the cause. Have the existing condition assessed first. A device intended for new-scale control should not be sold as an on-demand repair for a blocked or damaged component. Use the intended simultaneous duty after the fault is addressed. Selecting only from a restricted present flow can understate the real household requirement. No pressure increase is promised. Check available pressure and the losses across all installed components at the required flow. No. TDS describes dissolved solids and does not locate a restriction. Record flow, pressure, the affected branches and the equipment inspection findings. Record normal flow immediately after the completed repair or service, then track subsequent deposits and maintenance over comparable use. Keep the two observations distinct.Low Hot-Water Flow: Check Deposits Before Adding Scale Control

Separate fault finding from WD001 suitability screening
Water source
Protected equipment
Existing treatment
Parameter WD001 selection requirement What to check Total hardness <450 mg/L as CaCO3 A water report can describe scale-forming conditions but cannot locate an obstruction. TDS <800 ppm Measure separately from hardness; a TDS reading is not a pressure or flow test. Iron (Fe) <2 mg/L Assess staining, particles and necessary pretreatment separately from the flow complaint. pH 3-10 Review the measured value and equipment requirements without treating it as proof of the fault. Simultaneous flow 3 m³/h recommended; 4 m³/h maximum Use intended normal demand after the restriction has been addressed, not the reduced present flow as the design target. Supply pressure <1.0 MPa (<10 bar) Have available operating pressure assessed with the complete treatment train, including losses across existing equipment. Symptom pattern Document one outlet versus several, and hot versus cold A qualified installer should compare observations and check local fittings, heater components and pipework before identifying the cause. Size for the required duty after service
Outlet Number in use Flow per outlet Combined flow Bathroom showers 2 8 L/min 16 L/min Kitchen tap 1 6 L/min 6 L/min Utility tap 1 5 L/min 5 L/min Plan the installation around your existing system
Installation checklist
Confirm the site layout
WD001 whole-house scale control
Parameter Published model data Recommended flow 3 m³/h / 50 L/min Maximum flow 4 m³/h / approximately 66.7 L/min Connection options DN20: G3/4-inch male; DN25: G1-inch male (BSPP) Pressure limit <1.0 MPa / <10 bar Published inlet-temperature range 5-105°C; confirm the supplied version and actual installation conditions Body length 255 mm; allow additional room for fittings, valves and removal Electrical supply for WD001 Not required Salt replenishment or regeneration chemicals for WD001 Not required 
Set an appropriate expectation for scale control
What to assess
Know the treatment boundaries
Bring the information that changes the recommendation
Share the flow complaint and the existing system layout
Common selection questions
Does normal cold flow and weak hot flow prove that the heater is scaled?
Can I add WD001 before cleaning a blocked heater?
Should the unit be sized using the weak flow I currently measure?
Will the device raise my water pressure?
Can a TDS meter tell me which pipe is blocked?
How should I separate the benefit of a repair from scale control?
No salt refillsNo electrical supplyMain-line installation
Illustrative sizing example
Example simultaneous demand27 L/min = 1.62 m³/h
01Incoming supplyConfirm water quality and pressure
02Required pretreatmentSelected from the water report
03WD001 scale controlCheck flow, connection and access
04Household branchesCold fixtures and the water heater