RESIDENTIAL SCALE CONTROL Choose main-line scale control using your water report, simultaneous household demand and available installation space. This guide explains how to assess WD001 for pipes, water heaters and household fixtures. 01 / APPLICATION FIT Municipal water or well water with the necessary pretreatment Domestic storage, tankless or heat-pump water heater; confirm the actual equipment during selection Check existing filters, iron treatment, storage tanks and booster pumps before confirming the layout. These are product-selection limits. A full water assessment may identify other treatment needs. 02 / SIMULTANEOUS DEMAND Daily water consumption and bathroom count do not establish peak flow by themselves. List the outlets likely to run together, use their measured or specified flow rates, and add the demands. The example below is illustrative; replace these inputs with your installation data. Compare the calculated demand with the model's recommended flow, then confirm water quality, available pressure and connection. WD001 is rated at 3 m³/h (50 L/min) recommended and 4 m³/h (approximately 66.7 L/min) maximum. Maximum flow should not be treated as a recommended continuous design duty. 03 / MAIN-LINE LAYOUT For whole-house protection, assess a position on the incoming line after required pretreatment and before the branches serving the protected fixtures and water heater. 04 / MODEL REFERENCE Check the supplied version against the water report, hydraulic duty and installation conditions. 05 / PERFORMANCE CHECKS 06 / BEFORE SELECTION Send the information you have, including a water report and a main-line photo or sketch. Our team can review the connection, demand and installation position for your residential project or product range. WD001 is a physical scale inhibitor. It does not remove calcium and magnesium or reduce measured hardness like an ion-exchange softener. Bathroom count is only a starting point. Check which outlets can run together, their flow rates, the water report and the available pressure. A unit on the heater inlet addresses that downstream hot-water branch. Whole-house protection requires a suitable main-line position before the protected branches. Minerals remain in the water and can leave residue as droplets dry. Examine hard-scale adhesion and cleaning intervals rather than expecting every surface to become spot-free. Take dated baseline photos, note cleaning intervals and keep heater settings and usage comparable where practical. Ask the service technician to record deposits during normal equipment inspections.Whole-House Descaler Sizing and Installation Guide

Check water quality before choosing a model
Water source
Protected equipment
Existing treatment
Parameter WD001 selection requirement What to check Total hardness <450 mg/L as CaCO3 Use a water-analysis result, not a TDS reading. TDS <800 ppm Check separately from hardness. Iron (Fe) <2 mg/L Review iron, manganese and sediment treatment when needed. pH 3-10 Check the measured value and other water-quality concerns. Flow 3 m³/h recommended; 4 m³/h maximum Check simultaneous demand and pressure loss for the selected connection. Supply pressure <1.0 MPa (<10 bar) Include static pressure, pump operation and pressure transients. Size for outlets used at the same time
Outlet Number in use Flow per outlet Combined flow Showers 2 8 L/min 16 L/min Kitchen tap 1 6 L/min 6 L/min Other simultaneous outlet 1 8 L/min 8 L/min Plan the installation around your existing system
Installation checklist
Confirm the site layout
WD001 whole-house scale control
Parameter Published model data Recommended flow 3 m³/h / 50 L/min Maximum flow 4 m³/h / approximately 66.7 L/min Connection options DN20: G3/4-inch male; DN25: G1-inch male (BSPP) Pressure limit <1.0 MPa / <10 bar Published inlet-temperature range 5-105°C; confirm the supplied version and actual installation conditions Body length 255 mm; allow additional room for fittings and removal Electrical supply Not required Salt or regeneration chemicals Not required 
Set an appropriate expectation for scale control
What to assess
Know the treatment boundaries
Bring the information that changes the recommendation
Check the model and layout for your installation
Common selection questions
Will WD001 make my water softer?
Can I select the unit from the number of bathrooms?
Can it be installed before my water heater only?
Why might I still see white water marks?
How should I check the result?
No salt refillsNo electrical supplyMain-line installation
Illustrative sizing example
Example simultaneous demand30 L/min = 1.80 m³/h
01Incoming supplyConfirm water quality and pressure
02Required pretreatmentSelected from the water report
03WD001 scale controlCheck flow, connection and access
04Household branchesCold fixtures and the water heater