RESIDENTIAL SCALE CONTROL

Whole-House Descaler Sizing and Installation Guide

Choose main-line scale control using your water report, simultaneous household demand and available installation space. This guide explains how to assess WD001 for pipes, water heaters and household fixtures.

No salt refillsNo electrical supplyMain-line installation
Illustration of a whole-house descaler on the incoming supply serving household fixtures

01 / APPLICATION FIT

Check water quality before choosing a model

Water source

Municipal water or well water with the necessary pretreatment

Protected equipment

Domestic storage, tankless or heat-pump water heater; confirm the actual equipment during selection

Existing treatment

Check existing filters, iron treatment, storage tanks and booster pumps before confirming the layout.

WD001 water-quality and duty checks
ParameterWD001 selection requirementWhat to check
Total hardness<450 mg/L as CaCO3Use a water-analysis result, not a TDS reading.
TDS<800 ppmCheck separately from hardness.
Iron (Fe)<2 mg/LReview iron, manganese and sediment treatment when needed.
pH3-10Check the measured value and other water-quality concerns.
Flow3 m³/h recommended; 4 m³/h maximumCheck simultaneous demand and pressure loss for the selected connection.
Supply pressure<1.0 MPa (<10 bar)Include static pressure, pump operation and pressure transients.

These are product-selection limits. A full water assessment may identify other treatment needs.

02 / SIMULTANEOUS DEMAND

Size for outlets used at the same time

Daily water consumption and bathroom count do not establish peak flow by themselves. List the outlets likely to run together, use their measured or specified flow rates, and add the demands. The example below is illustrative; replace these inputs with your installation data.

Illustrative sizing example
OutletNumber in useFlow per outletCombined flow
Showers28 L/min16 L/min
Kitchen tap16 L/min6 L/min
Other simultaneous outlet18 L/min8 L/min
Example simultaneous demand30 L/min = 1.80 m³/h

Compare the calculated demand with the model's recommended flow, then confirm water quality, available pressure and connection. WD001 is rated at 3 m³/h (50 L/min) recommended and 4 m³/h (approximately 66.7 L/min) maximum. Maximum flow should not be treated as a recommended continuous design duty.

03 / MAIN-LINE LAYOUT

Plan the installation around your existing system

For whole-house protection, assess a position on the incoming line after required pretreatment and before the branches serving the protected fixtures and water heater.

01Incoming supplyConfirm water quality and pressure
02Required pretreatmentSelected from the water report
03WD001 scale controlCheck flow, connection and access
04Household branchesCold fixtures and the water heater

Installation checklist

  1. Record the water source, existing treatment, static pressure and proposed pipe connection.
  2. Check the water report and simultaneous demand before selecting the model.
  3. Inspect and service existing blocked fixtures or heavily scaled heating equipment as needed.
  4. Allow for the device, mating fittings, isolation valves and an accessible bypass where appropriate.
  5. Have a qualified installer isolate and depressurize the line, install the selected version and check for leaks and normal flow.

Confirm the site layout

  • The layout shown is a concept, not an installation drawing.
  • If the property has a storage tank, booster pump, hot-water recirculation or multiple treatment stages, send the actual layout for review.
  • Confirm thread standard and sealing method. BSPP and NPT connections must not be assumed interchangeable.
  • Protect the unit from freezing and physical damage, and keep joints and valves accessible.
  • Follow the water-heater manufacturer's service and installation instructions.

04 / MODEL REFERENCE

WD001 whole-house scale control

Check the supplied version against the water report, hydraulic duty and installation conditions.

Model reference for selection
ParameterPublished model data
Recommended flow3 m³/h / 50 L/min
Maximum flow4 m³/h / approximately 66.7 L/min
Connection optionsDN20: G3/4-inch male; DN25: G1-inch male (BSPP)
Pressure limit<1.0 MPa / <10 bar
Published inlet-temperature range5-105°C; confirm the supplied version and actual installation conditions
Body length255 mm; allow additional room for fittings and removal
Electrical supplyNot required
Salt or regeneration chemicalsNot required
View WD001 specifications and documents
ScaleDp WD001 inline water descaler

05 / PERFORMANCE CHECKS

Set an appropriate expectation for scale control

What to assess

  • Help reduce the formation of new, hard, tightly bonded mineral deposits.
  • Assess results using deposit adhesion, fixture cleaning intervals and water-heater inspections.
  • Retain calcium and magnesium in the water; measured hardness and TDS are not expected to decrease.

Know the treatment boundaries

  • Mineral spotting and some cleaning can continue when water dries on exposed surfaces.
  • Existing blocked plumbing or heavily scaled equipment may need cleaning or repair first.
  • Scale control does not remove dissolved salts, disinfect water or repair low supply pressure.
  • Choose ion-exchange softening when the required outcome is reduced hardness or a soft-water feel.
  • Water-quality limits screen suitability; they do not guarantee a particular field result.

06 / BEFORE SELECTION

Bring the information that changes the recommendation

  • Water source and current treatment equipment
  • Total hardness as CaCO3, TDS, iron and pH; alkalinity and other relevant results when available
  • Simultaneous outlet demand in L/min or m³/h
  • Pipe size, thread standard and available installation length
  • Supply pressure, pump or tank arrangement and inlet-water temperature
  • Water-heater type and a photo or sketch of the proposed installation
  • Quantity, destination and any distributor or project-document requirements

Check the model and layout for your installation

Send the information you have, including a water report and a main-line photo or sketch. Our team can review the connection, demand and installation position for your residential project or product range.

Request a Selection Review

Common selection questions

Will WD001 make my water softer?

WD001 is a physical scale inhibitor. It does not remove calcium and magnesium or reduce measured hardness like an ion-exchange softener.

Can I select the unit from the number of bathrooms?

Bathroom count is only a starting point. Check which outlets can run together, their flow rates, the water report and the available pressure.

Can it be installed before my water heater only?

A unit on the heater inlet addresses that downstream hot-water branch. Whole-house protection requires a suitable main-line position before the protected branches.

Why might I still see white water marks?

Minerals remain in the water and can leave residue as droplets dry. Examine hard-scale adhesion and cleaning intervals rather than expecting every surface to become spot-free.

How should I check the result?

Take dated baseline photos, note cleaning intervals and keep heater settings and usage comparable where practical. Ask the service technician to record deposits during normal equipment inspections.

Model data: ScaleDp WD001 product specifications. Water-quality limits: the current WD001 selection criteria supplied by the manufacturer. The sizing calculation is an illustrative example, not a measured customer case. These selection limits are not drinking-water safety standards.