RESIDENTIAL SCALE CONTROL A tankless heater can concentrate the scale-control discussion on its heat exchanger, but the selection decision starts with the incoming water and the complete household demand. This guide explains where WD001 may fit, how whole-house protection differs from a heater-only branch, and which heater maintenance requirements still need to be followed. 01 / APPLICATION FIT Municipal water, or well water after the pretreatment required by its analysis. Use results representing the proposed WD001 inlet and check the heater manual against the same supply; the acceptable range for one device does not establish suitability for the other. Residential gas or electric tankless water heater. Record the exact model, incoming-water temperature, intended hot-water delivery temperature, minimum activation flow and any recirculation arrangement before final equipment selection. List the sediment filter, iron or manganese treatment, existing softener, pressure-control equipment, heater inlet screen, service valves and recirculation components. Retaining a heater-required softener may be necessary even when a physical scale inhibitor is being considered. These are product-selection limits. A full water assessment may identify other treatment needs. 02 / SIMULTANEOUS DEMAND The example below assumes two mixed showers, a kitchen tap and a washbasin operating together. The fixture flows are hypothetical. A main-line descaler sees the household supply demand, while the tankless heater sees only the hot-water portion determined by mixing temperatures and use. WD001 recommended flow is 3 m³/h (50 L/min); maximum flow is 4 m³/h (approximately 66.7 L/min). Use the recommended duty for selection, then check pressure loss and water quality. Maximum flow is not a continuous-design recommendation. The example totals 26 L/min (1.56 m³/h). It is not a tankless-heater capacity rating: verify heater output at the required temperature rise, and confirm adequate flow to activate the heater at the lowest intended draw. 03 / MAIN-LINE LAYOUT For protection of both hot- and cold-water branches, assess WD001 after required pretreatment and before those branches divide. A unit installed only on the cold inlet to the tankless heater addresses that downstream hot-water circuit. Confirm the actual route before describing an installation as whole-house treatment. 04 / MODEL REFERENCE Check the supplied version against the water report, hydraulic duty and installation conditions. 05 / PERFORMANCE CHECKS 06 / BEFORE SELECTION Send the heater model, manual requirements, water report, simultaneous demand and installation photos. Our team can review the WD001 connection and main-line duty, identify the information still missing, and clarify whether the proposed position serves the whole house or only the heater branch. Do not assume that it can. WD001 retains calcium and magnesium. If the heater requirement is reduced measured hardness or a named treatment, obtain confirmation for that exact heater before changing the specification. A heater-inlet unit serves that downstream hot-water circuit. A suitable main-line position before the protected branches can serve both hot- and cold-water uses. Confirm the actual pipe route. No. That is a WD001 model limit. Heater delivery depends on its heating capacity, temperature rise and other operating conditions. Check the heater specification separately. Keep the heater maintenance requirements in place. Review any proposed change with the heater supplier using service observations and water-quality information. It will describe hardness in the supply, but WD001 is not designed to reduce that reading. Assess deposits and maintenance observations on the protected circuit instead. No. It shows an existing equipment arrangement. The image does not provide a controlled test, a complete water report or heater-manufacturer approval.Whole-House Scale Control for Tankless Water Heaters

Check the descaler and tankless heater requirements together
Water source
Protected equipment
Existing treatment
Parameter WD001 selection requirement What to check Total hardness <450 mg/L as CaCO3 Measure hardness as CaCO3 and compare it with the heater manual; the heater requirement may be stricter. TDS <800 ppm Check independently from hardness. A TDS reading cannot confirm that the heater receives softened water. Iron (Fe) <2 mg/L Review iron and suspended deposits before selecting pretreatment; WD001 does not remove them. pH 3-10 Confirm the heater requirements and any corrosion concerns separately from this product range. Simultaneous flow 3 m³/h recommended; 4 m³/h maximum Use combined household demand for a main-line unit. Calculate the actual hot-water load separately. Supply pressure <1.0 MPa (<10 bar) Include static pressure, operating pressure and other treatment losses. Heater requirement Follow the manual for the exact model Confirm water-quality limits, required treatment, service access and maintenance before approving the layout. Separate main-line demand from hot-water heating duty
Outlet Number in use Flow per outlet Combined flow Mixed shower 2 8 L/min 16 L/min Kitchen tap 1 6 L/min 6 L/min Washbasin tap 1 4 L/min 4 L/min Plan the installation around your existing system
Installation checklist
Confirm the site layout
WD001 whole-house scale control
Parameter Published model data Recommended flow 3 m³/h / 50 L/min Maximum flow 4 m³/h / approximately 66.7 L/min Connection options DN20: G3/4-inch male; DN25: G1-inch male (BSPP) Pressure limit <1.0 MPa / <10 bar Published inlet-temperature range 5-105°C; confirm the supplied version and actual installation conditions Body length 255 mm; allow additional room for fittings, valves and removal Electrical supply for WD001 Not required Salt replenishment or regeneration chemicals for WD001 Not required 
Set an appropriate expectation for scale control
What to assess
Know the treatment boundaries
Bring the information that changes the recommendation
Review the tankless heater supply and scale-control position
Common selection questions
Can WD001 replace a softener required by my heater manufacturer?
Where is the difference between heater-only and whole-house installation?
Does a 4 m³/h maximum mean my heater can deliver that much hot water?
Can I stop flushing or cleaning the heater after installation?
Will a hardness test demonstrate the scale-control effect?
Does the installation photograph prove a particular lifetime or saving?
No salt refillsNo electrical supplyMain-line installation
Illustrative sizing example
Example simultaneous demand26 L/min = 1.56 m³/h
01Incoming supplyConfirm water quality and pressure
02Required pretreatmentSelected from the water report
03WD001 scale controlCheck flow, connection and access
04Household branchesCold fixtures and the water heater