RESIDENTIAL SCALE CONTROL Repeated white residue on faucets, shower outlets and glass can lead homeowners to expect a completely spot-free bathroom after treatment. This page sets a more useful objective: assess new hard-scale adhesion, understand which hot- and cold-water branches are treated, and compare cleaning observations without confusing scale control with hardness removal. 01 / APPLICATION FIT Municipal water or appropriately pretreated well water. Check the water actually supplied to the bathroom branches. Iron or manganese staining, sediment and other causes of discoloration need separate assessment rather than being grouped together as limescale. The household storage, tankless or heat-pump water heater serving the showers and basins. Note whether the reported residue appears on hot-water outlets, cold-water outlets or both, and whether a central mixing valve or recirculation loop is present. Record existing filters and softeners, bathroom point-of-use devices, heater-only treatment, shower flow restrictors and any bypassed cold-water branches. An existing heater-inlet unit should not be assumed to treat the separate cold supply to a mixer tap. These are product-selection limits. A full water assessment may identify other treatment needs. 02 / SIMULTANEOUS DEMAND A large overhead shower, a second bathroom and a basin may overlap during morning use. Use measured or fixture-specified rates for the actual pressure. The following example is illustrative and does not describe a customer installation. WD001 recommended flow is 3 m³/h (50 L/min); maximum flow is 4 m³/h (approximately 66.7 L/min). Use the recommended duty for selection, then check pressure loss and water quality. Maximum flow is not a continuous-design recommendation. This example totals 22 L/min (1.32 m³/h). Add any other simultaneous demand, including kitchen or utility outlets, before confirming a main-line model. A low-flow showerhead does not reduce demand from other fixtures. 03 / MAIN-LINE LAYOUT To address both supplies feeding bathroom mixers, assess a main-line position after necessary pretreatment and before the hot- and cold-water branches divide. If only the heater inlet is treated, identify the untreated cold-water contribution instead of describing every mixed outlet as fully protected. 04 / MODEL REFERENCE Check the supplied version against the water report, hydraulic duty and installation conditions. 05 / PERFORMANCE CHECKS 06 / BEFORE SELECTION Share fixture photos, your water report, simultaneous demand and a sketch of the hot and cold branches. We can review the main-line position and WD001 fit, and help define what should be recorded when assessing recurring bathroom deposits. Calcium and magnesium remain in the water. As droplets evaporate, residue can remain on glass or metal. Evaluate new hard-scale adhesion and cleaning observations rather than requiring every surface to stay spotless. WD001 does not remove hardness minerals. If a soft-water feel or reduced hardness is the purchasing requirement, compare a suitable softener using the actual water analysis. Not automatically. The cold supply can bypass that device. Whole-house coverage needs a suitable position before the relevant hot and cold branches divide. Only with the relevant context. Record dates, cleaning, water use and photography conditions. Unmatched pictures can illustrate a concern, but they do not isolate treatment performance. There is no universal interval. Follow the fixture instructions and record actual deposit buildup and cleaning effort. Do not stop necessary cleaning while waiting for a scale-control effect. No. Investigate iron, manganese, corrosion, surface damage and other causes as appropriate. A scale inhibitor does not replace the treatment or repair selected for those findings.Whole-House Scale Control for Showers and Bathroom Fixtures

Check suitability and define the bathroom outcome
Water source
Protected equipment
Existing treatment
Parameter WD001 selection requirement What to check Total hardness <450 mg/L as CaCO3 Use a measured result; lower hardness is not the expected WD001 outcome. TDS <800 ppm Dissolved minerals can still leave residue when droplets evaporate. Iron (Fe) <2 mg/L Review colored staining separately; this limit is not an iron-removal or stain-free specification. pH 3-10 Record the actual result and investigate other material or corrosion concerns separately. Simultaneous flow 3 m³/h recommended; 4 m³/h maximum Include showers and taps likely to run together, not the bathroom count alone. Supply pressure <1.0 MPa (<10 bar) Check pressure available at the fixtures after the complete treatment train. Requested result Reduced new adherent scale If the requirement is lower measured hardness or a soft-water feel, review ion-exchange softening instead. Count the bathroom outlets that can run together
Outlet Number in use Flow per outlet Combined flow Overhead shower 1 9 L/min 9 L/min Second bathroom shower 1 8 L/min 8 L/min Washbasin tap 1 5 L/min 5 L/min Plan the installation around your existing system
Installation checklist
Confirm the site layout
WD001 whole-house scale control
Parameter Published model data Recommended flow 3 m³/h / 50 L/min Maximum flow 4 m³/h / approximately 66.7 L/min Connection options DN20: G3/4-inch male; DN25: G1-inch male (BSPP) Pressure limit <1.0 MPa / <10 bar Published inlet-temperature range 5-105°C; confirm the supplied version and actual installation conditions Body length 255 mm; allow additional room for fittings, valves and removal Electrical supply for WD001 Not required Salt replenishment or regeneration chemicals for WD001 Not required 
Set an appropriate expectation for scale control
What to assess
Know the treatment boundaries
Bring the information that changes the recommendation
Check treatment coverage for your bathroom fixtures
Common selection questions
Why can white drying marks remain after scale-control treatment?
Will showering feel the same as using an ion-exchange softener?
Does a device before the water heater protect the cold side of my shower mixer?
Can I compare two bathroom photographs to prove the result?
How often will I need to clean the showerhead?
Should every brown or black stain be called limescale?
No salt refillsNo electrical supplyMain-line installation
Illustrative sizing example
Example simultaneous demand22 L/min = 1.32 m³/h
01Incoming supplyConfirm water quality and pressure
02Required pretreatmentSelected from the water report
03WD001 scale controlCheck flow, connection and access
04Household branchesCold fixtures and the water heater