A comparative trial maintained stable RO performance while reducing chemical consumption and cleaning demands.
ScaleDp has shared results from a thermal power plant trial in which physical scale control replaced antiscalant dosing in RO Train A.

Comparing Physical and Chemical Scale Control
From September 5, 2024, to April 25, 2025, RO Train A operated with ScaleDp and no antiscalant dosing. Train B retained conventional treatment, consuming 25 kg of 5× concentrated antiscalant solution daily.
Maintaining Pressure and Permeate Quality
Both trains recorded a second-stage differential pressure of 60 kPa, with stable salt rejection and permeate conductivity. Train A met the project’s pressure-growth target.
Reducing Chemical Costs and Cleaning Demand
Zero dosing in Train A exceeded the target of at least 40% antiscalant savings. Estimated annual chemical savings reached RMB 90,000, based on 360 operating days and RMB 10/kg.
The reported membrane cleaning interval increased by approximately 50%, helping reduce maintenance demands.
Moving Toward Wider Application
With a reported payback of about one year, the plant subsequently purchased additional ScaleDp equipment to expand its application.